Home » Vacuum Components » Vacuum Pump » Oil Rotary Vacuum Pump » Oil Rotary Vacuum Pump VS650A / VS750A
Two models, 650m3/h and 750m3/h are available. Larger displacement can be obtained with combination of mechanical booster pump.
The VS series eliminates the need for costly facility work. The pump can be installed on an upper floor.
Construction of oil tank is simple and easy to clean.
Oil mist trap is inside oil tank. Cartridge type filter is easily replaced.
An oil cooler is used to reduce oil temperature increasing pump life.
Specifications | VS650A-A | VS650A-W | VS750A-A | VS750A-W | |||
Design evacuation speed m3/h(L/min) |
50Hz | 650(10833) | 750(12500) | ||||
60Hz | 750(12500) | n/a | |||||
Ultimate pressure *1 Pa |
GP close | 8 Pa | |||||
GP1 open | ≦50 | ||||||
GP1-2 open | ≦60 | ||||||
Max. water vapor tolerance *2 Pa |
GP1 open | 50Hz | 4500 | 2500 | 5500 | 2500 | |
60Hz | 5500 | 2500 | n/a | ||||
GP1-2 open | 50Hz | 6000 | 3800 | 7500 | 4000 | ||
60Hz | 7500 | 4000 | n/a | ||||
Max. water vapor capacity *2 kg/h |
GP1 open | 50Hz | 17 | 11 | 24 | 13 | |
60Hz | 24 | 13 | n/a | ||||
GP1-2 open | 50Hz | 26 | 15 | 34 | 19 | ||
60Hz | 34 | 19 | n/a | ||||
Motor *3 | Type | Totally enclosed external fan 3 phase AC motor | |||||
kw(Poles) | 22(4) | ||||||
Power consumption kW *6 | 50Hz | 200~240/380~415 | |||||
60Hz | 200~240/380~460 | n/a | |||||
Oil *4 | ULVOIL R-7 | ||||||
Oil capacity L | 23~27 | 25~30 | 23~27 | 25~30 | |||
Cooling method | Air cooled | Water cooled | Air cooled | Water cooled | |||
Cooling water | Primary side pressure MPa | - | ≥0.5 | - | ≥0.5 | ||
Inlet/outlet differential pressure MPa | - | ≥0.1 | - | ≥0.1 | |||
Capacity L/min | - | ≥3.0 | - | ≥3.0 | |||
Temperature °C | - | 5~30 | - | 5~30 | |||
Inlet | DN100 ISO-K | ||||||
Outlet | DN100 ISO-K | ||||||
Weight kg | 806 | 800 | 802 | 796 | |||
External dimensions W×D×H mm |
1490×905×705 | 1490×841×705 | 1490×905×705 | 1490×841×705 | |||
Applicable standard | CE/cTUVus | ||||||
Standard accessories | Oil for one pump, 1 set of instruction manual | ||||||
Options | explosion-protection motor, flame-proof motor, specified voltage motor, JIS flange *5, gas ballast valve 2 (manual) |
Model | PMB2400D +VS650A-A |
PMB2400D +VS650A-W |
PMB2400D +VS750A-A |
PMB2400D +VS750A-W |
|||
Design evacuation speed m3/h(L/min) |
50Hz | 2500(41667) | 3100(51667) | ||||
60Hz | 3100(51667) | n/a | |||||
Ultimate pressure *1 Pa |
GP close | ≤0.8 | |||||
GP1 open | ≤5 | ||||||
GP1-2 open | ≤6 | ||||||
Max. water vapor tolerance *2 Pa |
GP GP1 open |
50Hz | 1200 | 750 | 1600 | 700 | |
60Hz | 1600 | 700 | n/a | ||||
GP GP1-2 open |
50Hz | 2500 | 1200 | 2800 | 1200 | ||
60Hz | 2800 | 1200 | n/a | ||||
Max. water vapor tolerance *2 kg/h |
GP GP1 open |
50Hz | 16 | 10 | 24 | 11 | |
60Hz | 24 | 11 | n/a | ||||
GP GP1-2 open |
50Hz | 26 | 15 | 34 | 19 | ||
60Hz | 34 | 19 | n/a | ||||
Motor *3 | Type | Totally enclosed external fan 3 phase AC motor | |||||
kW(Poles) | MBP:7.5(2)+ RP:22(4) | ||||||
Power consumption kW *6 | 50Hz | 9 | 12 | ||||
60Hz | 12 | n/a | |||||
Voltage V | 50Hz | 200~240/380~415 | 200~240/380~415 | ||||
60Hz | 200~240/380~460 | n/a | |||||
Oil *4 | MBP:ULVOIL R-4+RP:ULVOIL R-7 | ||||||
Oil capacity L | MBP:3.6~4.0 RP:23~27 |
MBP:3.6~4.0 RP:25~30 |
MBP:3.6~4.0 RP:23~27 |
MBP:3.6~4.0 RP:25~30 |
|||
Cooling method | Air cooled *7 | Water cooled | Air cooled *7 | Water cooled | |||
Cooling water | Primary side pressure MPa | - | ≥0.5 | - | ≥0.5 | ||
Inlet/outlet differential pressure MPa | - | ≥0.1 | - | ≥0.1 | |||
Capacity L/min | MBP:≥3.0 PR:≥3.0 |
≥3.0 | - | MBP:≥3.0 PR:≥3.0 |
|||
Temperature °C | - | 5~30 | - | 5~30 | |||
Inlet | VG200/DN 160 ISO-K (option) | ||||||
Outlet | DN100 ISO-K | ||||||
Weight kg | 1076 | 1070 | 1072 | 10666 | |||
External dimensions W×D×H mm |
1490×905×1260 | 1490×841×1260 | 1490×905×1260 | 1490×841×1260 | |||
Applicable standard | CE/cTUVus | ||||||
Standard accessories | Oil for one pump, 1 set of instruction manual | ||||||
Options | [For MBP] explosion-protection motor,flame-proof motor,specified voltage motor,ISO flange, Atmospheric pressure start type (Inverter) MBP adapter |
*1 Measured with a Pirani vacuum gauge.(Approx. 0.8Pa when measured with a McLeod vacuum gauge.)
*2 Water vapor tolerance and capacity are measured under following cooling water capacity. Cooling water temperature at inlet port is 26°C (78.8F).
Model | VS650A-W | VS750A-W | |
GP1 open | 50Hz | 3 L/min. | 5 L/min. |
60Hz | 5 L/min. | - | |
GP1・2 open | 50Hz | 3 L/min. | 5 L/min. |
60Hz | 5 L/min. | - |
*3 Increased safety explosion-resistant motor and pressure proof explosion-resistant flange motor are available as option. However, multiple voltage cannot be selected.
*4 Other oil types are available, upon request.
*5 Size to connect pipe changes when JIS flange is selected for inlet/outlet port.
*6 At ultimate pressure
*7 Only with inverter. At 400-50000Pa, the pumping speed specification of air cooled is reduced than that of the water cooled.
Address: 110/6 Moo.13 Soi 25/2
Kingkaew Rd.,Rachathewa,
Bangplee,Samutprakan 10540
TEL: +66 2 738 8883
FAX: +66 2 738 8200