Small Oil Rotary Vacuum Pump GCD Series

GCD Series, direct drive, oil rotary vacuum pump is corrosion resistant for toxic and corrosive gases which is ideal for chemical, pharmaceutical applications. Surface of gas contacted parts are coated with hard plating. Three different sizes are available from 50L to 200L/min.

features

  • Chemical type of Oil rotary pump with surface treatment on the gas contact surface.

  • Connectable to oil filtration system.

  • Low noise and low vibration.

  • The backflow prevention mechanism prevents oil from flowing back to the vacuum chamber when it is stopped due to a power failure.

  • The exhaust speed is stable due to the installation of the forced oil supply mechanism.

  • Operation from atmospheric pressure is possible.

  • Easy connection with flanged parts and connection by knock pins on internal parts.

Specifications

ModelUnitGCD-051XGCD-136XGCD-201X
 50Hz60Hz50Hz60Hz50Hz60Hz
Actual Pumping SpeedL/min5060135162200240
Ultimate pressure※1 G.V.Closed

0.67

 G.V.Open6.7
 Motor Single phase, 100V, 200W, 4P, Split phase startingSingle phase, 100V, 400W, 4P, Capacitor start/runThree phase, 200V, 700W, 4P
 Full load currentA5.64.87.76.13.453.08
Oil CapacitymL500~8001,0001,100
Recommended oil SO-M
Weightkg14.125.426.6
Inlet port diametermmKF-25
Ambient temperature7~40
External dimensionsmm165.5(W)×419(L)×222.7(H)170(W)×493(L)×241.1(H)170(W)×509.5(L)×241.1(H)
※1:Ultimate pressure is measured by Pirani gauge.(In the case of measurement by McLeod gauge, the value is lower by an order of magnitude for pumps with an Ultimate pressure of 1.3 Pa or less.)
 

Corresponding certificate/Voltage

ModelApplicable standardCE
Declartion of confirmity

100V

115V

200V

220V

230V

200V
GCD-051X
GCD-136X ○* ○*
GCD-201X

●:Standard、○:Option、-:Not Applicable
※Please consult with us regarding the safety expansion motor.

Caution

Oil is deteriorated with operating, and becomes the factor of performance shortage.
A decrease and the dirt of oil are confirmed, and please regularly add and replace it.
A backflow preventer is incorporated into the pump to prevent the oil from flowing back while the pump is stopped.
Please make a suction side into atmospheric pressure when the pump is stopped for a long time.
If operation is performed at high pressure, oil mist is generated at the exhaust side.
We will recommend the use of the oil mist separator for the oil mist splash prevention.
The influence might go out to the pump life according to the characteristic and the amount of the evacuated gas.
Especially, longevity is remarkably shortened, and corrosion resistance might not be able to be demonstrated about ammonia and sulfuric acid.
It is not suitable for the pump if operation is performed continuously at a high evacuation pressure of 1kPa or more.
There is a risk of explosion. Never block the outlet or operate the pump with equipment mounted at the outlet side that blocks the passage of gas.
Otherwise, the internal pump pressure increases causing the pump to explode, the oil level gauge to protrude or the motor to be overloaded.
Same parts of the pump are made by carbon.
Oil becomes black with wear-out powder of carbon parts, when operation is doing. But it doesn’t affect the performance and service life of the pump.
Fluoride rubber material is used for the internal parts of a pump. There are some for which the chemical resistance of Fluoride rubber materialis not suitable. Especially, be careful of the following chemical.
Ammonia, Acetone, Ethylene oxide, Ethylene diamine, Zinc acetate, Amyl acetate, Aluminum acetate, Isopropyl acetate, Ethyl acetate, Lead acetate, Calcium acetate, Cellosolve Acetate, Nickel acetate, Butyl acetate, Propyl acetate, Methyl acetate, Nitroethane, Nitropropane, Nitromethane, Freon.

Dimension / Drawing

GCD-051X
GCD-136X
GCD-201X

Pumping Speed Curve